What was found
CRACK ON INTERCOSTAL- WEB FLOOR STRUCTURE LOCATED BTW BS 277 TO BS 294.5 LBL 2.5 AT FWD GALLEY AREA 2023-180825<[01] REPLACED INTERCOSTAL- WEB FLOOR STRUCTURE LOCATED BTW BS 277 TO BS 294.5 LBL 2.5 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 141A5400 SHEET 26 REV -<BR>SEE INDIVIDUAL SIGN OFF BELOW;[02] CORRECTED STEP 1<BR>REPLACED INTERCOSTAL- WEB FLOOR STRUCTURE LOCATED BTW BS 277 TO BS 294.5 LBL 2.5 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 141A5400 SHEET 20 REV - <BR>SEE INDIVIDUAL SIGN OFF BELOW;[03] JOB COMPLETED AND CERTIFIED RII.