As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PASS. CABIN FLOOR PANEL 231XF HAS PULLED FIBERS UPPER SURFACE<[01] FABRICATED NEW FLOOR BOARD 231XF USING BMS 4-17 TY6 LOT#1514505-1; INSTALLED INSERTS AND CURED USING BMS 5-107 LOT#AK2KP8383K AND THERMOMETER ID:ATS2208 DUE:10/23; PART MARKED; AND APPLIED TAPE IAW SRM 53-00-50-2R-0 PARA 1.A(NOTE);5.S AND BDWG 144A5810-126.;[02] VERIFIED CORRECTIVE ACTION #1