What was found
AFT CARGO DOOR CUTOUT LOWER WEB UPPER SURFACE CORROSION BETWEEN STA 794.3-847 RBL 25'<[01] EVALUATED AREA AT AFT CARGO DOOR CUTOUT LOWER WEB STA 794.3-847<BR>FOUND CORROSION EXFOLIATED OUT OF LIMITS PER SRM 53-60-15-1A-1<BR>RECEIVED; LOCATED AND DRILLED NEW AFT CARGO DOOR CUTOUT LOWER WEB STA 794.3-847 (PN: 146A8123-25) PO:1792296 PER SRM 51-40-05-0G-0<BR>TREATED AND PRIMED NEW FASTENER HOLES PER AMM 51-21-41-370-803 AND 51-21-72-370-804;[02] FINAL INSPECTION; VERIFIED STEP #1. ALL WORK PERFORMED.