What was found
MULTIPLE AREA OF CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 727+5-727E+7 WL 155.<[01] SRM 53-00-53-1A-2 FOUND TO BE APPLICABLE<BR><BR>UPDATED MEASUREMENT TABLE;[02] REMOVED MULTIPLE AREA OF CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 727+5- BS727E+7 WL 155. DEEPEST BLEND AT BS 727C +2. L= 0.5' W=0.5' D=0.012'. REMAINING THICKNESS 0.028'. ORIGINAL THICKNESS 0.040'. <BR>FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REPAIR BY REPLACEMENT;[03] REMOVED MULTIPLE AREA OF CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 727+5- BS727E+7 WL 155. DEEPEST BLEND AT BS 727C +2. L= 0.5' W=0.5' D=0.012'. REMAINING THICKNESS 0.028'. ORIGINAL THICKNESS 0.040'.<BR>FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REPAIR BY REPLACEMENT<BR><BR>DEPTH GAUGE ID: ATS2678 DUE: 02/29/24;[04] EDITED MEASUREMENT TABLE #19;[05] VERIFIED CORRECTIVE ACTION ITEMS 1-4 AND VERIFIED MEASUREMENT TABLE;[06] TASK WILL BE COMPLETED AT CUSTOMER CARD # TTG8Q00JE0ZS;[07] VERIFIED CORRECTIVE ACTION 6