What was found
STIFFENER P/N 111A1308-16 IS CRACKED BS 663 RH VAPOR BARRIER RBL 25 W/L 148<[01] VERYFIED APPLICABILITY IAW SRM 53-10-10-1A-2 ALLOWABLE DAMAGE; FOUND OUT OF LIMITS IAW SRM 53-10-10-1A-2; 4(E);[02] REMOVED STIFFENER P/N 111A1308-16 IAW SRM 51-40-02-0G-0.<BR>UPDATED MEASUREMENT TABLE.;[03] LOCATED AND DRILLED NEW STIFFENER P/N 111A1308-16 IAW SRM 51-40-05-0G-0 AND DWG 111A1000. REQUEST OK TO INSTALL.;[04] EDIT CORRECTIVE ACTIION STEP 1; CRACK ON STIFFENER BS 663 RBL 25 WL 148 IT'S OUT OF LIMITS NOT ARE LIMITS GIVEN IN THE SRM BY REPAIRED BY REPLACEMENT OF PART IAW SRM 51-10-02 PAR 9.;[05] VERIFIED CORRECTIVE ACTION 4 AND MEASUREMENT TABLE;[06] VERIFIED CORRECTIVE ACTION 3. OK TO INSTALL.;[07] INSTALLED NEW STIFFENER AT BS 663; RBL 25; WL 148 IAW SRM 51-40-02 AND DWG: 111A1000 AND DWG: 149A7210.;[08] APPLICABILITY STATEMENT IAW SRM 57-10-10-1A-2 ;4 (E) FOR ALLOWABLE DAMAGE;[09] VERIFIED CORRECTIVE ACTION 7 INSTALLATION;[10] VERIFIED CORRECTIVE ACTION 8 APPLICABILITY;[11] SIGNED FOR PART;[12] TASK COMPLETE