What was found
CORROSION ON FLOOR SUPPORT AT FWD CABIN BS270+6 LBL11 WL208.<[01] EVALUATED DAMAGE ON FLOOR SUPPORT AT FWD CABIN BS270+6 LBL11 WL208; FOUND TO BE OUT OF LIMITS; DUE NOT LIMITS IN SRM PART WILL BE REPAIRABLE BY REPLACEMENT; IAW SRM 51-10-02-0G-0;[02] REMOVED FLOOR SUPPORT AT FWD CABIN BS270 LBL11 WL208; IAW SRM 51-40-02-0G-0;[03] LOCATED AND DRILLED NEW FLOOR SUPPORT P/N 141A5670Y12 IAW SRM 51-40-05-0G-0 AND DWG 141A5670; OK TO INSTALL;[04] VERIFIED CORRECTIVE ACTION ITEM 1-3; OK TO INSTALL.;[05] INSTALLED NEW FLOOR SUPPORT AT FWD CABIN BS 270 TO BS 277 LBL11 WL208; IAW SRM 51-40-02-0G-0 DWG 141A5600; CARD IS COMPLETED;[06] RII VERIFIED CORRECTIVE ACTION ITEM 5.;[07] VERIFIED CORRECTIVE ACTION ITEMS AND MEASUREMENT FIELDS; CARD COMPLETE.