What was found
CRACKED INTERCOSTAL AT FWD CABIN BS312+5 RBL31 WL208.<[01] CRACKED INTERCOSTAL AT FWD CABIN BS312+5 RBL 31; WL 208.1 FOUND 100% OUT OF LIMITS IAW SRM 51-10-02;[02] REMOVED INTERCOSTAL FROM BS312-BS344 RBL 31 IAW SRM 51-40-02;[03] VERIFIED CORRECTIVE ACTION 1;[04] RECEIVED; LOCATED AND DRILLED NEW INTERCOSTAL <BR>P/N 141A5410-12 IAW SRM 51-40-05 AND DWG 141A5400<BR>OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION 4.<BR>OK TO INSTALL;[06] INSTALLED NEW INTERCOSTAL AT BS312+5 RBL 31 WL 208<BR>P/N 141A5410-12 IAW SRM 51-40-02-0G-0 AND DWG 141A5400;[07] VERIFIED CORRECTIVE ACTION STEP 1;[08] ALL STEPS COMPLETE