What was found
CRACKED INTERCOSTAL AT FWD CABIN BS344+6 BL0 WL208.<[01] VERIFIED APPLICABILITY OF SRM 53-10-51-1A-1 ALLOWABLE DAMAGE 1 - SECTION 41 FLOOR STRUCTURE;[02] ACCOMPLISHED EVALUATION OF CRACK ON INTERCOSTAL AT FWD WET AREA PASSENGER CABIN FLOOR STRUCTURE STA344+6'' BL0 WL208 AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-51-1A-1 PART 4.E(1) FIG.205 L=0.8'' TOOL USED CALIPER ID: ATS2739 S/N: A22004232 DUE DATE: 11/2023.<BR>PART REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 PART 9.A(1).;[03] REMOVED INTERCOSTAL AT FWD WET AREA STA344 TO 360 BL0 WL208 IAW SRM 51-40-02-0G-0.;[04] LOCATED AND DRILLED NEW INTERCOSTAL P/N 141A5410-23 IAW SRM 51-40-05-0G-0 AND DWG#141A5400; REFER TO EA 1-753-34884.;[05] TRIM OUT ON NEW INTERCOSTAL IAW SRM 51-10-02-0G-0 REFER TO EA 1-753-34884.;[06] VERIFIED CORRECTIVE ACTIONS 1; 2; 4; 5; AND MEASUREMENT TABLE.;[07] HFEC INSPECTED TRIM OUT ON NEW INTERCOSTAL PER NDTM PT6 51-00-00 PROCEDURE 23; NO CRACKS NOTED<BR>EQUIP ID IS000680 DUE 04/2023;[08] OK TO TREAT AND PRIME TRIM OUT AREAAPPLIED CHEMICAL CONVERSION COATING AND PRIME ON TRIM OUT AREA IAW SRM 51-20-01-0G-0 AND SOPM 20-41-02.<BR>OK TO INSTALL. INSTALLED INTERCOSTAL AT FWD CABIN FROM BS344-BS360 BL0 IAW SRM 51-40-02 AND IAW DWG#141A5400 AND REFER TO EA#1-753-34884 INCORRECT COLLARS USED FOR INTERCOSTAL INSTALLATION.;[14] CORRECTIVE ACTION 13 REJECTED IN ERROR; CORRECT COLLARS USED.;