What was found
AFT CARGO BAY - RAIL HAS CORROSION BS 767+5 LBL 7.75; LBL 12; RBL 3.<[01] VERIFIED APLICABILITY SRM 53-60-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE;[02] COMPLETED STEPS 1-3.<BR><BR>OK TO APPLY CHEMICAL CONVERSION COATING AND PRIMER.;[03] VERIFIED CORRECTIVE ACTIONS 1;2 AND STEPS 1-3. VERIFIED MEASUREMENT TABLE.;[04] APPLIED CHEMICAL CONVERSION COATING AND PRIMER PER SRM#53-00-53-1A-2 STEPS 2.E.(1)-(2);[05] VERIFIED CORRECTIVE ACTION ITEM 4. MEASUREMENT FIELD REMAINING THICKNESS STATES 0.060'; NOT CORRECT PER SUB-STEPS 1 AND 2; HAS 0.059' AS REMAINING THICKNESS.;[06] UPDATED MEASUREMENT TABLE TO REFLECT 0.059';[07] SEE CORRECTIVE ACTION 6: UPDATED MEASUREMENT TABLE TO REFLECT 0.059';[08] VERIFIED CORRECTIVE ACTION ITEMS AND MEASUREMENT FIELDS; CARD COMPLETE.