What was found
MULTIPLE AREA OF CORROSION ON FWD CARGO BAY FWD DOOR SHIELD AT RBL 24 BS 420-440 WL 157.<[01] VERIFIED SRM 51-10-02 PARAG 9. IS APPLICABLE FOR REPAIRABLE BY REPLACEMENT.;[02] CORROSION ON FWD CARGO BAY FWD DOOR SHIELD LOCATED BETWEEN BS 420-BS 440 RBL24.FOUND TO BE OUT OF LIMITS;PART HAS NOT SRM LIMITS IS REPAIRABLE BY REPLACEMENT PER SRM 51-10-02 PARAG 9.;[03] VERIFIED CORRECTIVE ACTIONS 1 AND 2;[04] SHIELD ASSY. RECEIVED. P/N 143A8126-21; LOT:1510082-1.<BR> LOCATED AND DRILLED BETWEEN BS 420 - BS 440 RBL 24 WL156 IAW SRM 51-40-05 AND DWG# 143A0080.;[05] ALL MAINTENANCE ACTION ARE COMPLETE REQUEST FINAL BUY OFF.;[06] VERIFIED CORRECTIVE ACTION 4 AND MEASUREMENT TABLE