What was found
BAFFLE IS CRACKED BETWEEN BS500B TO 500C LBL24 WL158<[01] VERIFIED SRM 51-10-02 PARA: G 9; IS APPLICABLE BY REPLACEMENT.;[02] PRIOR TO REMOVAL FOUND PART HAS NOT SRM LIMITS AND SO PART IS REPAIRABLE BY REPLACEMENT; IAW SRM 51-10-02 PARA: G 9.;[03] REMOVED BAFFLE DAMAGED BETWEEN BS 500B - BS 500C LBL 24<BR>WL 158 IAW 51-40-02;[04] RECEIVED; LOCATED AND DRILLED NEW BAFFLE<BR>WITH P/N 143A7510-11 LOT#1519664-3 <BR>IAW SRM 51-40-05 AND DWG 143A7510<BR>OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION ITEM; OK TO INSTALL.;[06] INSTALLED BAFFLE AT FWD CARGO BAY BS500B-BS 500C LBL24 WL 158 IAW SRM 51-40-02 AND DWG 143A7510;[07] VERIFIED CORRECTIVE ACTION 6 AND MEASUREMENT TABLE