What was found
CRACK FLOOR BEAM LOCATED BS294.5 AND RBL52 WL208.1 AT FWD GALLEY AREA 2023-191877<[01] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 25-JAN-24; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 01-FEB-24.;[02] TOOL USED: EDDY CURRENT INSTRUMENT P/N: NORTEC 600D; S/N: 220272512; DUE DATE: 17-DEC-23;[03] TOOL USED RADIOMETER PN. XRP 3000; SN. 1859843; DUE DATE. 04-MAY-23;[04] PERFORMED PERMANENT REPAIR FLOOR BEAM LOCATED BS294.5 AND RBL52 WL208.1 AT FWD GALLEY AREA IAW B737-700 SRM 53-10-51-2R-16 REPAIR 16; AND DWG # 141A5502 REV:- SEE INDIVIDUAL SIGN-OFFS BELOW.;[05] PERFORMED PERMANENT REPAIR FLOOR BEAM LOCATED BS294.5 AND RBL52 WL208.1 AT FWD GALLEY AREA IAW B737-700 SRM 53-10-51-2R-16 REPAIR 16; AND DWG # 141A5502 REV:- SEE INDIVIDUAL SIGN-OFFS BELOW.RII CERTIFIED