What was found
AFT CABIN FLOOR PANEL 242VF I/B AFT EDGE IS BROKEN.<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 6 TABLE 6.<BR>FOUND ADDITIONAL DAMAGE ACROSS UPPER SURFACE AND MULTIPLE AREAS ON LOWER SURFACE; ALL DAMAGE WAS FOUND TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR>REMOVED ALL INSERTS ON PANEL TO FACILITATE REPAIRS IAW SRM 53-00-50-2R-0 PARA 5.B(2).<BR>REMOVED ALL DAMAGED SKIN PLIES AND CORE ON UPPER AND LOWER SURFACE IAW SRM 53-00-50-2R-6 PARA 3.C; DAMAGE AT I/B AFT EDGE EXCEEDS PERMITTED DAMAGE SIZE. REQUESTED PANEL REPLACEMENT.;[02] COMPLETED ALL STEPS OF EA 23-153-00978.;[03] VERIFIED CORRECTIVE ACTION 1; 2 AND MEASUREMENT TABLE.