What was found
AFT CARGO COMPARTMENT - MULTIPLE AREA OF CORROSION ON SIDEWALL SUPPORT AT BS 727 TO BS 767 RBL 21.75 WL 155. (MARKED)<[01] VERIFIED APPLICABILITY FOR IDENTIFICATION IAW SRM 53-60-53-0I-2<BR>AND ALLOWABLE DAMAGE IAW SRM 53-00-53-1A-2;[02] REMOVED CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21.75 BS 727A+2' WL 155<BR>DIMENSIONS L=.900' W= .700' DEPTH:0.020'<BR>ORIGINAL MATERIAL THICKNESS 0.040' IAW BAC 1496-377 REMAINING THICKNESS: 0.020'<BR>AND FOUND TO BE OUT OF LIMITS; IAW SRM 53-00-53-1A-2<BR>TOOL USED: ID ATS 1698 S/N: 1505370 DUE: 05/2023;[03] VERIFIED CORRECTIVE ACTION STEPS 1 AND 2.;[04] RECEIVED ZEE CHANNEL P/N 146A7502-51 LOT: 1519356-2.<BR>LOCATED AND DRILLED AT AFT CARGO COMPARTMENT FLOOR TO SIDEWALL SUPPORT BETWEEN BS 727 - BS 767RBL 21.75 WL. 155 IAW SRM 51-40-05 DWG# 146A7500.;[05] THE INSTALLATION WILL BE ACCOMPLISHED WITH CUSTOMER CARD # TTG8Q0049HEA;[06] UPDATED PARTS USAGE;[07] VERIFIED CORRECTIVE ACTION ITEMS AND MEASUREMENT FIELDS; CARD COMPLETE.