What was found
AFT CARGO COMPARTMENT - MULTIPLE AREA OF CORROSION ON FLOORBOARD SPLICE STRAP AT BS 887 FROM LBL 6.5 TO LBL 18.5 WL 155. (MARKED)<[01] VERIFIED APPLICABILITY FOR SRM 51-10-02 PARAG 9.;[02] CORROSION ON ACB;FLOORBOARD SPLICE STRAP AT BS887 FROM LBL 6.5 TO LBL18.5;WL155.FOUND TO BE OUT OF LIMITS;PART HAS NOT ALLOWABLE DAMAGE ON SRM;PART IS REPAIRABLE BY REPLACEMENT PER SRM 51-10-02 PARAG 9.;[03] CONCUR WITH APPLICABILITY OF SRM 51-10-02 PARA.9.<BR>VERIFIED CORRECTIVE ACTION ITEM 2.<BR>VERIFIED MEASUREMENT TABLE COMPLETED.;[04] RECEIVED; LOCATED; DRILLED AND INSTALLED<BR>NUTPLATES ON NEW SPLICE STRAP<BR>P/N 146A9401-39 LOT#1467489<BR>IAW SRM 51-40-05 AND SRM 51-40-02<BR>AND DWG 146A7500;[05] VERIFIED CORRECTIVE ACTION #4