What was found
CRACK STRINGER 25R LOCATED BS540 FWD CARGO COMPARTMENT 2023-200269<[01] TOOL USED ULTRASONIC EQUIPMENT: P/N: 45MG; S/N: 221860711; DUE DATE: 07-NOV-23.;[02] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 25-JAN-24; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 01-FEB-24.;[03] EQUIPMENT P/N PHASEC 3D; S/N 800YBRK; DUE DATE: 22-APR-23 WAS USED.;[04] PERFORMED PERMANENT REPAIR ON STRINGER 25R BETWEEN BS 500C TO BS 540 FWD CARGO COMPARTMENT IAW B737-700 SRM 53-00-03-2R-1 REPAIR 1.SEE INDIVIDUAL SING OFF BELOW.;[05] TASK COMPLETED ; RII <BR>SEE INDIVIDUAL SING OFF BELOW