What was found
CORROSION ON ANGLE AT MID CABIN BS713 LBL63; LBL65 WL203.< REMOVED FOR ACCESS 2EA RIVET AT MID CABIN BS713 LBL63; LBL65 TO REMOVED CORROSION ON ANGLE SURFACE I.A.W SRM 51-40-02-0G-0;[03] REMOVED CORROSION ON ANGLE SURFACE AT MID CABIN BS713 LBL63 1'X1' AREA AND LBL65 1''X1'' AREA WL203 I.A.W SRM 51-10-02-0G-0;>LBL65: MINIMUM REMAINING MATERIAL THICKNESS FOUND 0.070' ADJACENT TO 0.071';[07] EQUIPMENT USED:<BR>-NORTEC 600 ID: ATS1465 CAL DUE: 09/2023<BR>-EPOCH 650 ID: ATS2342 CAL DUE: 07/2023;[08] EDITING DAMAGE DIMENSION MEASUREMENTS. REMOVED CORROSION ON ANGLE SURFACE AT MID CABIN BS713 LBL63 1'X 0.55' AREA AND LBL65 1''X 0.5'' AREA WL203 I.A.W SRM 51-10-02-0G-0.;[09] VERIFIED CORRECTIVE ACTION 8;[10] REFER TO FAULT TTG8Q00K8Y5T WHERE EA 23-153-01208 WAS ADDED AS A SUBTASK.;[11] VERIFIED CORRECTIVE ACTION 10;[12] EDITED MEASUREMENT TABLE FOR POTENTIAL CORROSION LEVEL.;[13] VERIFIED MEASUREMENT TABLE