What was found
CRACK ON INTERCOSTAL WEB LOCATED FLOOR STRUCTURE BTW BS 312 TO BS 328 LBL 46.5 AT FWD GALLEY AREA 2023-219700<[01] REPLACED INTERCOSTAL WEB AND FASTENERS LOCATED FLOOR STRUCTURE BTW BS 312 TO BS 328 LBL 46.5 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 Ï¿½TEM 9;SRM 51-40-02 AND DWG 141A5400 SHEET 26 REV.- SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED INTERCOSTAL WEB AND FASTENERS LOCATED FLOOR STRUCTURE BTW BS 312 TO BS 328 LBL 46.5 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 Ï¿½TEM 9;SRM 51-40-02 AND DWG 141A5400 SHEET 26 REV.- SEE INDIVIDUAL SIGN OFF BELOW. AS RII