What was found
CRACK ON SUPPORT ANGLE LOCATED BTW BS 291.5 TO BS 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA 2023-219704<[01] REPLACED NEW SUPPORT ANGLE AND FASTENERS LOCATED BTW BS 291.5 TO BS 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 Ï¿½TEM 9 AND DWG 141A8310 SHEET 25 REV B . SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED NEW SUPPORT ANGLE AND FASTENERS LOCATED BTW BS 291.5 TO BS 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 Ï¿½TEM 9 AND DWG 141A8310 SHEET 25 REV B . SEE INDIVIDUAL SIGN OFF BELOW.<BR>RII