What was found
CRACK ON INSPAR RIB LOCATED STAB STA 129.50 AND 1 INCH FROM FRONT SPAR AT UPPER CHORD FLANGE AREA ON LT HORIZONTAL STAB 2023-219812<[01] TOOL USED: EDDY CURRENT INSTRUMENT P/N: NORTEC 600D; S/N: 220272512; DUE DATE: 17-DEC-23;[02] TOOL USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811019 DUE DATE: 25-JAN-24.TEMPERATURE CONTROLLER P/N P3015GOES00000 DUE DATE: 25-JAN-24.;[03] INSPAR RIB LOCATED STAB STA 129.50 AND 1 INCH FROM FRONT SPAR AT UPPER CHORD FLANGE AREA ON LT HORIZONTAL STAB EA 23-155-01202 WIP1 AND EA 23-155-01202 SEE INDIVIDUAL SIGNOFFS BELOW;[04] CORRECTED STEP 3 REPAIRED INSPAR RIB LOCATED STAB STA 129.50 AND 1 INCH FROM FRONT SPAR AT UPPER CHORD FLANGE AREA ON LT HORIZONTAL STAB EA 23-155-01202 WIP1 AND EA 23-155-01202 SEE INDIVIDUAL SIGNOFFS BELOW;[05] CORRECTED STEP 4 REPAIRED INSPAR RIB LOCATED STAB STA 129.50 AND 1 INCH FROM FRONT SPAR AT UPPER CHORD FLANGE AREA ON LT HORIZONTAL STAB IAW EA 23-155-01202 WIP1 AND EA 23-155-01202 SEE INDIVIDUAL SIGNOFFS BELOW;[06] REPAIRED INSPAR RIB LOCATED STAB STA 129.50 AND 1 INCH FROM FRONT SPAR AT UPPER CHORD FLANGE AREA ON LT HORIZONTAL STAB IAW EA 23-155-01202 WIP1 AND EA 23-155-01202 SEE INDIVIDUAL SIGNOFFS BELOW TASK RII CERTIFIED COMPLETE