What was found
AFT CARGO COMPARTMENT FLOOR AT STA 747; RBL 21; WL 156 FRAME HAS ELONGATED HOLE.<[01] REAMED UP ELONGATED HOLES ON DAMAGED FRAME AT STA. 747 PER REF. SRM 53-60-07-2R-2; FINAL HOLE DIAMETER ON UPPER HOLE 0.247' AND ON LOWER HOLE 0.247'; VENIER CALIPER USED B/C 174952; CAL DUE DATE. 15-JUL-23; FABRICATED REPAIR STRAP AND LOCATED NEW FASTENER HOLES IN REF B737-700 SRM 53-60-07-2R-2; LOCATED AND DILLED REPAIR PARTS IN REF B737-700 SRM 53-60-07-2R-2; INSTALLED HEX DRIVE BOLTS WET WITH BMS 5-95 P/N PS870B2-60Z SEALANT PER REF. SRM 53-60-07-2R-2; MIXED TIME 19:10 AND APPLIED TIME 19:12; 04/21/2023 AND INSTALLED FASTENERS ON REPAIR PART WITH BMS 5-95 P/N PS870B2-60Z SEALANT BETWEEN THE MATING SURFACES PER REF. SRM 53-60-07-2R-2.;[02] VERIFIED STEP # 1; VERIFIED REPEAT INSPECTION AT THRESHOLD.