What was found
CRACK ACCESS DOOR 834 LOWER FWD ANGLE AT LOWER FUSELAGE 2023-208661<[01] REPLACED ACCESS DOOR 834 LOWER FWD ANGLE AT LOWER FUSELAGE DUE TO NOT FOUND ALLOWABLE DAMAGE LIMITS IN B737-700 SRM FOR CRACK; IAW 737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02 AND DWG 411A2119 SHEET 72 REV - . MEASURE OF CRACK IS : 0.295? TOOL USED DIGITAL CALIPER P/N:500-196-30; S/N A21126170; DUE DATE:09NOV23;[02] REPLACED ACCESS DOOR 834 LOWER FWD ANGLE AT LOWER FUSELAGE DUE TO NOT FOUND ALLOWABLE DAMAGE LIMITS IN B737-700 SRM FOR CRACK; IAW 737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02 AND DWG 411A2119 SHEET 72 REV - . MEASURE OF CRACK IS : 0.295? TOOL USED DIGITAL CALIPER P/N:500-196-30; S/N A21126170; DUE DATE:09NOV23