What was found
FORWARD CARGO THRESHOLD BEADED WEB HAS SEVERAL AREAS OF CORROSION. (MARKED)<[01] REMOVED DAMAGE I.A.W SRM 51-10-02. MEASURED DAMAGE DEPTH TO BE .009?. DAMAGE FOUND TO BE OUT OF LIMITS I.A.W SRM 53-30-15-1A-1.;[02] REMOVED FORWARD CARGO THRESHOLD WEB I.A.W SRM 51-40-02.;[03] LOCATED AND DRILLED REPLACEMENT THRESHOLD WEB (MPN 654A0003-58) I.A.W SRM 51-40-05. COUNTERSUNK APPLICABLE FASTENER HOLES I.A.W SRM 51-40-08.;[04] OK ON CA#3<BR>3. DUSTIN WYATT (TECHNICIAN); 12-APR-2023 22:12 UTC<BR>LOCATED AND DRILLED REPLACEMENT THRESHOLD WEB (MPN 654A0003-58) I.A.W SRM 51-40-05. COUNTERSUNK APPLICABLE FASTENER HOLES I.A.W SRM 51-40-08;[05] REMOVED AND REPLACED FORWARD CARGO THRESHOLD BEADED WEB PER SRM 51-40-02;[06] INSPECTED WORK PERFORMED