What was found
DOT A114-017. CABIN FLOORBOARD 231XF HAS AREAS WITH PULLED FIBERS ON UPPER SURFACE.<[01] EVALUATED PANEL 231XF AND FOUND PULLED FIBERS ON UPPER SURFACE. FOUND TO BE REPAIRABLE. IAW B737-700 SRM 53-00-50-2R-1 PAR 1A. CLEAN AND PREP. IAW B737-700 SRM 53-00-50-2R-1 PAR 3A;C;E&F. VERIFY MATERIALS. BMS 8-201 (A178552); BMS 9-3 (A164924). IAW B737-700 SRM 53-00-50-2R-1 TABLE 201. NEED OK TO BOND.;[02] VERIFIED STEP 1 AND OK TO BOND;[03] BONDED REPAIR. IAW B737-700 SRM 53-00-50-2R-1 PAR 3K-M.;[04] REPAIRED AREA'S OF PULLED FIBERS ON UPPER SURFACE OF PANEL231XF. IAW B737-700 SRM 53-00-50-2R-1; SRM 53-00-50-2R-0.;[05] VERIFIED STEPS 3-4