What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED BS695 AND BL0 RH SIDE CENTER SECTION 2023-212637<[01] REPLACED ANGLE FLOOR STRUCTURE LOCATED BS695 AND BL0 RH SIDE CENTER SECTION IAW B737-700 SRM: 51-40-02 PARAGRAPH 9 DWG: 273A9110 SHEET: 3 REV: - . SEE INDIVIDUALS SIGN OFF BELOW.;[02] CORRECTED ESTEP 1: REPLACED ANGLE FLOOR STRUCTURE LOCATED BS695 AND BL0 RH SIDE CENTER SECTION IAW B737-700 SRM: 51-10-02 PARAGRAPH 9 AND 51-40-02 DWG: 273A9110 SHEET: 3 REV: - . SEE INDIVIDUALS SIGN OFF BELOW.;[03] CORRECTED STEP 2: REPLACED ANGLE FLOOR STRUCTURE LOCATED BS695 AND BL0 RH SIDE CENTER SECTION IAW B737-700 SRM: 51-10-02 PARAGRAPH 9 AND 51-40-02 DWG: 273A9110 SHEET: 3 REV: - . SEE INDIVIDUALS SIGN OFF BELOW.;[04] CERTIFIED STEP 3 COMPLETE RII <BR>REPLACED ANGLE FLOOR STRUCTURE LOCATED BS695 AND BL0 RH SIDE CENTER SECTION IAW B737-700 SRM: 51-10-02 PARAGRAPH 9 AND 51-40-02 DWG: 273A9110 SHEET: 3 REV: -