What was found
FLOOR PANEL 231ZF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 SHEET 1; FIGURE 4; TABLE 4.<BR><BR>UPON INVESTIGATION; PANEL DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM<BR>53-00-50-1A-1 PAR. 4. E. & 4. F.<BR><BR>DUE TO SIZE OF DAMAGE FABRICATING NEW PANEL FOLLOWING IAW SRM 53-00-50-2R-0 PAR. 1.A. NOTE:<BR><BR>FABRICATED NEW FLOOR BOARD USING BMS4-23 TY II LOT# 1508291-1; <BR>SANDED EDGES AND CLEANED IAW SRM 53-00-50-2R-0 PAR. 4.A.(2) <BR>TABLE 204; & 5.E. STILL NEED LOCATED INSERT DRILLING.<BR><BR>UPDATED MEASUREMENTS TABLE.;[02] LOCATED AND INSTALLED ALL INSERTS USING BMS 5-107 LOT#AK2KP8383K-1; CURED WITH THERMOMETER ID:ATS2208 CAL DUE 10/2023; PART MARKED PANEL IAW SRM 53-00-50-2R-0 PARA 5.S AND BOEING DWG 144A5810 ID:0020.;[03] VERIFIED CORRECTIVE ACTIONS 1 AND 2<BR><BR>VERIFIED MEASUREMENTS TABLE;[04] UPLOADED CURE SHEET. JOB COMPLETE;[05] VERIFIED CORRECTIVE ACTION 4