What was found
FOUND CORROSION AROUND THE FASTENER HOLE IN FLOOR STRUCTURE AFT WET AREA AT STA 951 ; LBL 19' (228-001)<[01] REMOVED AND INSTALLED NEW T ANGLE SUPPORT IN FLOOR STRUCTURE AFT WET AREA AT STA 951 LBL 19 AS PER SRM 51-40-02-0G-0 AND DWG # 147A5650 SHEET 54 REV A.;[02] REMOVED AND INSTALLED NEW T ANGLE SUPPORT IN FLOOR STRUCTURE AFT WET AREA AT STA 951 LBL 19 AS PER SRM 51-40-02-0G-0 AND DWG # 147A5650 SHEET 54 REV A.;[03] VERIFIED STEP #1. REMOVED AND INSTALLED NEW T ANGLE SUPPORT IN FLOOR STRUCTURE AFT WET AREA AT STA 951 LBL 19 AS PER SRM 51-40-02-0G-0 AND DWG # 147A5650 SHEET 54 REV A;[04] VERIFIED STEP 3. REMOVED AND INSTALLED NEW T ANGLE SUPPORT IN FLOOR STRUCTURE AFT WET AREA AT STA 951 LBL 19 AS PER SRM 51-40-02-0G-0 AND DWG # 147A5650 SHEET 54 REV A.