What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT ACB RBL21 BS727B+4; BS727C+14 - BS767 WL156.<[01] VERIFY APPLICABILITY PER SRM 53-60-53-0I-2 AND SRM 53-00-53-1A-2.<BR>REMOVED CORROSION ON DISCREPANCY AREA L=0.800';W=0.700';D=0.010'. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 AND SRM 51-10-02.<BR>TOOL USED: ID:ATS1672; DUE:MAR-31-2024;[02] VERIFIED CORECTIVE ACTION 1 AND THE MEASUREMENT TABLE.;[03] FABRICATED NEW FLOOR TO SIDEWALL SUPPORT AT ACB RBL 21 BS 727 TO BS 767 ITEM BAC1496-377#7075T62 LOT#1521599-1 IAW SRM 51-40-05 AND DWG 146A7502.<BR>OK TREAT AND PRIMER;[04] VERIFIED CORRECTIVE ACTION 3. OK TO TREAT AND PRIME.;[05] VERIFIED THE MEASUREMENT TABLE.;[06] APPLIED CHEMICAL CONVERSION COATING AND PRIMER IAW SRM 51-20-01 AND SOPM 20-41-02;[07] VERIFIED CORRECTIVE ACTION 6;[08] CORRECTED STEP 19 OF MESUREMENTS;[09] VERIFIED STEP 19 CORRECTION. CARD COMPLETE