What was found
CRACK ON FLOOR STRUCTURE INTERCOSTAL WEB LOCATED BTW BS 312 TO BS 328 LBL 46.5 AT FWD GALLEY AREA 2023-247677<[01] REPLACED INTERCOSTAL WEB FLOOR STRUCTURE LOCATED BTW BS 312 TO BS 328 RBL 35 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND SRM 51-10-02 ITEM 9 AND DRAWING # 141A5400 REV - . SEE INDIVIDUAL SIGNOFFS BELOW;[02] CORRECTED STEP 1 <BR>REPLACED INTERCOSTAL WEB FLOOR STRUCTURE LOCATED BTW BS 312 TO BS 328 LBL 46.5 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND SRM 51-10-02 ITEM 9 AND DRAWING # 141A5400 REV - . SEE INDIVIDUAL SIGNOFFS BELOW;[03] REPLACED INTERCOSTAL WEB FLOOR STRUCTURE LOCATED BTW BS 312 TO BS 328 LBL 46.5 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND SRM 51-10-02 ITEM 9 AND DRAWING # 141A5400 REV - . SEE INDIVIDUAL SIGNOFFS BELOW