What was found
CORROSION ON INTERCOSTAL WEB FLOOR STRUCTURE LOCATED BTW BS 294.5 TO BS 312 LBL 6 WL 208.1 AT FWD GALLEY AREA 2023-247679<[01] TOOL USED EDDY CURRENT FLAW DETECTOR P/N: NORTEC 600D; S/N: 200053402; DUE DATE: 13-MAY-23;[02] TOOL USED: THICKNESS GAGE P/N:45MG; S/N: 221861811; DUE DATE: 08-NOV-23.;[03] REPLACED INTERCOSTAL WEB FLOOR STRUCTURE LOCATED BTW BS 294.5 TO BS 312 LBL 6 WL 208.1 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 ; SRM 51-10-02 ITEM 9 AND DWG 141A5600 REV ?N? ; DWG 141A5400 REV ?B?.;[04] REPLACED INTERCOSTAL WEB FLOOR STRUCTURE LOCATED BTW BS 294.5 TO BS 312 LBL 6 WL 208.1 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 ; SRM 51-10-02 ITEM 9 AND DWG 141A5600 REV ?N? ; DWG 141A5400 REV ?B?.