What was found
CORROSION ON PLATE LOCATED BS 1016 PLUS 12 INCHES LBL 2 WL 208.1 AT AFT GALLEY AREA 2023-247696<[01] TOOL USED ; ULTRASONIC THICKNESS GAGE; P/N: 45MG; S/N: 130063701; CAL DUE DATE 16JUN23;[02] REPLACED PLATE (STRAP) AND FASTENERS LOCATED BS 1016 PLUS 12 INCHES LBL 2 WL 208.1 AT AFT GALLEY AREA I.A.W B737-700 SRM 51-40-02 AND DWG 147A5600 SHEET 32 REV B.<BR>SEE INDIVIDUAL SIGNOFFS BELOW;[03] TASK COMPLETED ; RII <BR>SEE INDIVIDUAL SIGNOFFS BELOW