What was found
CRACK ON INTERCOSTAL WEB FLOOR STRUCTURE LOCATED BTW BS 328 TO BS 344 LBL47 AT FWD GALLEY AREA 2023-237863<[01] REPLACED INTERCOSTAL WEB AND FASTENERS LOCATED FLOOR STRUCTURE BTW BS 328 TO BS 344 LBL47 AT FWD GALLEY AREA I.A.W B737-700 SRM 51-10-02 AND DWG 141A5400 SHEET 44; REV:- SEE INDIVIDUAL SIGN-OFFS BELOW.;[02] REPLACED INTERCOSTAL WEB AND FASTENERS LOCATED FLOOR STRUCTURE BTW BS 328 TO BS 344 LBL47 AT FWD GALLEY AREA I.A.W B737-700 SRM 51-10-02 AND DWG 141A5400 SHEET 44; REV:- SEE INDIVIDUAL SIGN-OFFS BELOW.RII Ï¿½TEM