What was found
INOP EMERGENCY LIGHT FWD ENTRY DOOR; FWD GALLEY; STOWAGE BIN 3 RH; EME RGENCY DOOR LH(2EA) AT PASSENGER CABIN 2023-238132<[01] PERFORMRD FIM 33-50 TASK 801 AND FOUND BURNED FUSE (3 3/A) ON POWER SUPPLY ;WERE REPLACED IAW B737-700 AMM 33-51-06-960-804 AND PERFORMED OPERATIONAL TEST EMERGENCY LIGHT IAW B737-700 AMM 33-51-00-710-801 AND TEST IS OK.;[02] PERFORMRD FIM 33-50 TASK 801 AND FOUND BURNED FUSE (3 3/A) ON POWER SUPPLY ;WERE REPLACED IAW B737-700 AMM 33-51-06-960-804 AND PERFORMED OPERATIONAL TEST EMERGENCY LIGHT IAW B737-700 AMM 33-51-00-710-801 AND TEST IS OK.