What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED BS 695 AND RBL 24.75 CENTER SECTION 2023-247580<[01] TOOL USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112820025; DUE DATE:01-FEB-24.;[02] REPLACED ANGLE FLOOR STRUCTURE LOCATED BS 695 AND RBL 24.75 CENTER SECTION IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 273A9110 SHEET 6 REV. A. SEE INDIVIDUAL SIGNOFFS BELOW.;[03] CORRECTED STEP 2: REPLACED ANGLE FLOOR STRUCTURE LOCATED BS 695 AND RBL 24.75 CENTER SECTION IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG 273A9110 SHEET 6 REV. A. SEE INDIVIDUAL SIGNOFFS BELOW.;[04] CERTIFIED STEP 3 COMPLETED <BR>RII