What was found
CORROSION WEB LOC ON FUELING STATION INTERNAL AREA OF PANEL 621GB AT RT WING 2023-238059<[01] REPLACED REFUEL STATION PANEL AND PERFORMED OPERATIONAL TEST IAW B737-700 AMM 28-41-61-400-801 TEST IS OK<BR>SEE INDIVIDUAL SIGN OFF STEP BELOW;[02] CORRECTED STEP 1<BR>REPLACED REFUEL STATION PANEL AND PERFORMED OPERATIONAL TEST IAW B737-700 AMM 28-41-61-000-801 AND AMM 28-41-61-400-801 TEST IS OK<BR>SEE INDIVIDUAL SIGN OFF STEP BELOW;[03] REPLACED REFUEL STATION PANEL AND PERFORMED OPERATIONAL TEST IAW B737-700 AMM 28-41-61-000-801 AND AMM 28-41-61-400-801 TEST IS OK <BR>SEE INDIVIDUAL SIGN OFF STEP BELOW<BR>TASKCARD COMPLETED