What was found
CORROSION AFT CARGO BAY ATTACH ANGLE UNDER SHIELD HAS MULTIPLE AREAS UNDER NUT PLATES BS767 TO BS787 RBL21 WL156<[01] CORROSION ON ANGLE WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION1.;[03] REMOVED DAMAGED AFT CARGO BAY ANGLE UNDER SHIELD BS767 TO BS787 RBL21 WL156 IAW SRM 51-40-02-0G-0;[04] LOCATED AND DRILLED NEW AFT CARGO BAY ANGLE UNDER SHIELD BS767 TO BS787 RBL21 WL156 IAW SRM 51-40-05-0G-0; DWG146A8123 AND DWG 146A0081. OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION 4 AND THE MEASUREMENT TABLE.;[06] INSTALLED AFT CARGO BAY ANGLE UNDER SHIELD BS767 TO BS787 RBL21 WL156 IAW SRM 51-40-02-0G-0; DWG146A8123 AND DWG 146A0081.;[07] VERIFIED CORRECTION ACTION ITEM 6.;[08] VERIFIED ALL CORRECTION ACTION CARD COMPLETE.