What was found
FRAME BS 312 CRACKED IN RADIUS; AT UPPER DOOR THRESHOLD STR 5 LH<[01] REMOVED DAMAGE IAW SRM51-10-02-OG.;[02] VERIFIED CORRECTION ITEM 1.;[03] REQUEST NDI FOR HFEC SERVICE SCAN TO VERIFY CRACK FREE CONDITION AT CUT OUT.;[04] HFEC INSPECTED CUTOUT AREA IAW 737 NDTM PART 6 51-00-00 PROCEDURE 23.<BR>NO CRACKS NOTED.<BR>EQUIP USED:<BR>-NORTEC 600 ID: ATS1465 CAL DUE: 09/23;[05] OK TO APPLY CHEMICAL CONVERSION AND PRIMER;[06] VERIFIED CORRECTION ITEM 5; OK TO APPLY CHEMICAL CONVERSION AND PRIMER.;[07] APPLIED CHEMICAL CONVERSION AND PRIMER IAW SRM 51-20-01-0G-0 & AMM 51-21-72-370-804;[08] VERIFIED CORRECTION ACTION ITEM 7; MEASURENT TABLE; COMPLETE.