What was found
FOUND CRACK ON INTERCOSTAL COMMON TO FASTENER HOLE AT BS 284.5 WL 208 BL 0<[01] UPDATED MEASUREMENT TABLE;[02] REMOVED INTERCOSTAL AT 208 BL 0 BS 277-294.5 AND LOCATED AND DRILLED NEW INTERCOSTAL PN:141A5410U3AAR; NEED OK TO INSTALL;[03] CERTIFY;[04] VERIFIED CORRECTION ACTIONS 1;2;3; AND OK TO INSTALL.;[05] INSTALLED NEW INTERCOSTAL BS277-294.5 BL0 IAW SRM 51-40-02-0G-0 AND DWG #141A5400 REV:-;[06] CERTIFY;[07] VERIFIED CORRECTIVE ACTION 5 AND MEASUREMENT TABLE