What was found
FOUND CRACK ON INTERCOSTAL COMMON TO FASTENER HOLE AT BS 321 WL 208 LBL 44<[01] UPDATED MEASUREMENT FIELD;[02] UPDATED MEASUREMENT TABLE;[03] CERTIFY;[04] REMOVED INTERCOSTAL AT WL208 LBL44 BS 312-328; LOCATED AND DRILLED NEW INTERCOSTAL PN:141A5410U12. NEED OK TO INSTALL.;[05] CERTIFY;[06] VERIFIED CORRECTION ACTIONS 2;3;4 AND 5 AND OK TO INSTALL.;[07] INSTALLED NEW INTERCOSTAL BS312-328 LBL44 IAW SRM 51-40-02-0G-0 AND DWG #141A5400 REV:-;[08] CERTIFY;[09] VERIFIED CORRECTIVE ACTION 7 AND MEASUREMENT TABLE