What was found
FWD PANEL 221DF UPPER FACESHEET HAS MULTIPLE AREAS OF PULLED STRANDS.<EXCEEDS THE ALLOWABLE DAMAGE LIMITS PER SRM 53-00-50-1A-1 PARA 4. B. PERFORMED DAMAGE REMOVAL & SURFACE PREPARATION IAW SRM 53-00-50-2R-1 PARA 4 STEPS A-F.;[03] UPDATED MEASUREMENTS;[04] VALIDATED REPAIR PER SRM 53-00-50-2R-1;[05] REMOVED 26EA THROUGH INSERTS & 6EA BLIND INSERTS USING BMS9-3 STYLE 1581 GLASS LOT 1522395-2 & BMS8-301/50A RESIN LOT 1523449-1 FABRICATED REPAIR PLIES IAW SRM 53-00-50-2R-1 PARA 3 STEPS K & LAID UP THE REPAIR VACUUM BAGGED THEN LEAK CHECKED IAW SRM 53-00-50-2R-1 PARA 3. L. STEPS (1) (A)-(C) CAL TOOL VACUUM GAGE ID ATS2798 CAL DUE 10/2023 & SET TO CURE;CURED REPAIR USING HEAT LAMP AND THERMOMETER ATS2208 CAL DUE DATE 10/2023; UNBAGGED; AND LIGHTLY SANDED THEN INSTALLED ALL THROUGH INSERTS USING BMS5-107 LOT#AK2KP8383K; REMOVED 3EA DAMAGED BLIND INSERTS THEN INSTALLED ALL NEW BLIND INSERTS USING POTTING BMS5-28 TYPE 19 LOT#AK2LP8414K IAW SRM 53-00-50-2R-1 PARA 3M(1)-N<BR><BR>INSERTS NEED CURE.;INSERTS REMOVED IN CORRECTIVE ACTION LINES 5 & 11 WERE REPLACED & CURED IAW SRM 53-00-50-2R-0 PARA 5 S. TABLE 203-PAGE 2 REF CAL TOOL THERMOMETER ID ATS2208 CAL DUE 10/2023;CABIN FLOOR PANEL 221DF UPPER SURFACE FACE SHEET WAS REPAIRED IAW SRM 53-00-50-2R-1;