What was found
FWD PANEL 222DF HAS A RIPPED OUT INSERT ALONG THE O/B EDGE. (MARKED)<OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F. FOUND ADDITIONAL DAMAGE ON THE INBOARD EDGE. FABRICATED AND CLEANED 2E HONEYCOMB CORE PLUGS USING BMS 8-124; TYPE V; GRADE 9.0; CLASS 4 LOT# 1287137 IAW SRM 53-00-50-2R-6 PARA 3.F AND TABLE 201; BWG DWG #: 141A5810 SHEET: 749] INSTALLED CORE PLUGS USING BMS 5-28 TY19 LOT: AK2IP3152K USING VACUUM AND CAUL PLATES TO SUPPORT THE REPAIRS IAW SRM 53-00-50-2R-6 PARA 3.F;H.;[09] CORRECTION TO ACTION 8: USED VACUUM GAUGE ATS2798 DUE: 10/2023;[10] INSPECTED AND VERIFIED CORRECTIVE ACTION 9.<BR>.;[11] 5067<BR><BR>UPPER SURFACE PLIES CURED AND UNBAGGED ON FAULT TTG8Q00KBKR7<BR><BR>SANDED 2EA HONEYCOMB CORE PLUGS TO BE LEVEL WITH THE ADJACENT SURFACES IAW SRM 53-00-50-2R-6 PARA 3.J. <BR><BR>FABRICATED REPAIR PLIES FROM BMS 9-3 TY H2 CL7 STYLE 1581 LOT#1522395-2-1 IAW SRM 53-00-50-2R-6 PARA 3.K(1) INSTALLED LOWER SURFACE REPAIR PLIES USING BMS8-201 LOT#1522301-1; VACUUM BAGGED; CHECKED FOR LEAKS; LEAK CHECKED GOOD USING VACUUM GAUGE ATS2798 CAL DUE DATE 10/2023 AND SET FOR CURE USING HEAT LAMP AND THERMOMETER ATS2208 CAL DUE DATE 10/2023 IAW SRM 53-00-50-2R-6 PARA 3K(1)-L(1)-M(1).;[15] INSPECTED AND VERIFIED CORRECTIVE ACTION 14.;[16] CURED USING HEAT LAMP AND THERMOMETER ATS2208 CAL DUE DATE 10/2023; UNBAGGED AND LIGHTLY SANDED REPAIR IAW SRM 53-00-50-2R-6 PARA 3M(1).;[17] INSERTS WERE INSTALLED AND CURED ON FAULT TTG8Q00KBKR7\\