What was found
FOUND 2 EA AREAS OF CORROSION ALONG MOP SEAL THRESHOLD I/B ATTACH PLATE FED AT BS 313.4-316 WL 208 LBL 59 AND BS 334-336.5 WL 208 LBL 62.5<[01] VERIFIED APPLICABILITY FOR SRM 53-10-15-1A-1;[02] REMOVED CORROSION ALONG MOP SEAL THRESHOLD I/B ATTACH PLATE FED AT <BR>BS 313.4-316 WL 208 LBL 59 LENGTH: 4.5' X WIDTH: 0.9' <BR>BS 334-336.5 WL 208 LBL 62.5 LENGTH: 3' X WIDTH: 0.9' PER SRM 53-10-15-1A-1 FIG. 103 DETAIL H;[03] REQUEST NDI FOR MATERIAL REMAINING THICKNESS; [06] REMOVED CORROSION ALONG MOP SEAL THRESHOLD I/B ATTACH PLATE FED AT<BR>BS 334-336.5 WL 208 LBL 62.5 LENGTH: 3' X WIDTH: 0.9' D:0.066' FROM ORIGINAL THICKNESS 0.080' FOUND TO BE OUT OF LIMITS PER SRM 53-10-15-1A-1 FIG. 103 DETAIL H<BR>3;[07] REMOVED MOP SEAL THRESHOLD I/B ATTACH PLATE FED AT BS 312-344 WL 208 LBL 60 PER SRM 51-40-02-0G-0;[08] VERIFIED CORRECTIVE ACTIONS STEP 6.;[09] RECEIVED FROM TOOL ROOM NEW FED MOP SEAL THRESHOLD I/B ATTACH PLATE P/N 141A8112U20; LOT# 1524424-1.<BR>LOCATED AND DRILLED PER SRM 51-40-05-0G-0 AND BOEING DWG# 141A8110. OK TO INSTALL.;[10] VERIFIED CORRECTIVE ACTION #9; OK TO INSTALL