As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LOSS OF SYSTEM B HYDRAULIC.<[01] REMOVED AND REPLACED B SYSTEM EMDP PER AMM 29-11-21; LEAK AND OPS CHECK GOOD;[02] CW FILTER CHANGE;[03] REF LP 0472836E FOR CLOSING ACTION; ITEM REMAINS OPEN;[04] REMOVE AND REPLACE 'B' EDP PER AMM 29-11-11. REMOVE AND REPLACE EDP HYDRAULIC PRESSURE LINE PER AMM 20-10-52. REPLACE SYSTEM B FILTERS PER AMM 29-11-00. NO LEAKS AND OPS CHECK GOOD. EV# E022550.