As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND ONE EXISTING HOLE AT LH WEB ENLONGATED FLIGHT DECK FLOOR WEB STA 258 LBL23 WL 208.1<[01] FINAL HOLE SIZE .281 DIAMETER ; AND INSTALLATION OF FASTENER PER EA 153-01579 WIP 1;[02] VERIFIED STEP 1; FINAL HOLE SIZE .281 AND FASTENER INSTALLED PER EA 153-01579 WIP 1;[03] ACCOMPLISHED EA 23-153-01579. REF FAULT TTG8Q00KYXAC