What was found
WING BOX CENTER SECTION - FLOOR SUPPORT HAS A CRACK BS 540 LBL 2<[01] REMOVED CRACKED WING BOX CENTER SECTION - FLOOR SUPPORT BS 540 BL 0 - LBL 25 IAW SRM 51-40-02;[02] LOCATED AND DRILLED NEW WING BOX CENTER SECTION - FLOOR SUPPORT BS 540 BL 0 - LBL 25 IAW SRM 51-40-05 AND DWG 143A5240 ; OK TO INSTALL;[03] VERIFIED CORRECTION ACTION ITEM 2; OK TO INSTALL GIVEN.;[04] INSTALLED NEW FLOOR SUPPORT PER SRM 51-40-05 AND DWG 143A5240;[05] VERIFIED CORRECTIVE ACTION 4.;[06] VERIFIED THE MEASUREMENT TABLE.