What was found
FLOOR PANEL 222DF UPPER SKIN HAS AN AREA OF PULLED STRANDS. (MARKED)<[01] IDENTIFIED FLOOR PANEL 222DF IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2 AND BOEING DWG 141A5810-749.<BR><BR>DAMAGE TO UPPER SURFACE SKIN PLIES IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARA 4B.<BR><BR>REPAIR TO BE ACCOMPLISHED PER SRM 53-00-50-2R-1.<BR><BR>REMOVED 26 THROUGH INSERTS TO FACILITATE REPAIR IAW SRM 53-00-50-2R-1 PARA 3B.<BR><BR>REMOVED DAMAGE TO UPPER SURFACE SKIN AND CLEANED AREA THEN FABRICATED REPAIR PLIES FROM BMS9-3H2ST1581 LOT#1522395-2; OK TO INSTALL IAW SRM 53-00-50-2R-1 PARA 3A-F AND PARA 3K(1).;[02] VALIDATED APPLICABILITY OF SRM 53-00-50-2R-1.;[03] INSPECTED AND VERIFIED CORRECTIVE ACTIONS 1 AND 2.;[04] INSTALLED REPAIR PLIES USING BMS8-201 TYPE 4 LOT#1524651-1; VACUUM BAGGED; CHECKED FOR LEAKS; LEAK CHECKED GOOD USING VACUUM GAUGE ATS2441 CAL DUE DATE 08/2023 IAW SRM 53-00-50-2R-1 PARA 3K(1)-L(1).;[05] INSPECTED AND VERIFIED CORRECTIVE ACTION 4.<BR><BR>VERIFIED MEASUREMENTS TABLE.;[06] CURED REPAIR USING HEAT LAMP AND THERMOMETER ATS2208 CAL DUE DATE 10/2023 THEN REMOVED VACUUM BAG IAW SRM 53-00-50-2R-1 PARA 3M(1).