What was found
AFT FLOOR PANEL 241AAF HAS MULTIPLE AREAS OF PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 241AAF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 6 TABLE 6. FLOOR PANEL 241AAF DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARAGRAPH 4.F. FLOOR PANEL UPPER SURFACE DAMAGE IS BEYOND ECONOMICAL REPAIR AND CAN BE REPLACED IAW SRM 53-00-50-2R-0 PARAGRAPH 1.A (NOTE). <BR><BR>FABRICATED AFT FLOOR PANEL 241AAF USING BMS4-17 TY6 LOT#1522265-1. INSTALLED INSERTS USING BMS5-107 LOT#AK2KP8383K AND CURED USING THERMOMETER ID:ATS2208 CAL DUE: 10/2023. INSTALLED TAPE GUA1057-1 LOT# 1515311-2; AND PART MARKED AS REQUIRED. IAW SRM 53-00-50-2R-0 PARAGRAPH 5.S(1); AND BAC DWG 147A5810 ID:008.<BR><BR>AFT FLOOR PANEL 241AAF UPPER SURFACE WAS DAMAGED BEYOND ECONOMICAL REPAIR AND WAS REPLACED BY FABRICATING A NEW PANEL IAW SRM 53-00-50-2R-0; AND BAC DWG 147A5810 ID:008.;[02] INSPECTED AND VERIFIED CORRECTIVE ACTION 1.;[03] ATTACHED CURE SHEET TO THIS FAULT RECORD.;[04] VERIFIED MEASUREMENTS TABLE.<BR><BR>JOB COMPLETE.