What was found
AFT FLOOR PANEL 242VF HAS MULTIPLE AREAS OF PULLED STRANDS<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 6 TABLE 6.<BR>FOUND MULTIPLE AREAS OF ADDITIONAL DAMAGE ON LOWER SURFACE; ALL DAMAGE FOUND TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR>ALL DAMAGE TO BE REPAIRED IAW SRM 53-00-50-2R-1.<BR>REMOVED ALL THROUGH INSERTS AND 1EA BLIND INSERT TO FACILITATE REPAIR IAW SRM 53-00-50-2R-1 PARA 3.B.<BR>REMOVED ALL DAMAGED SKIN AND LOOSE PIECES OF CORE ON UPPER AND LOWER SURFACE; CLEANED REPAIR AREAS IAW SRM 53-00-50-2R-1 PARA 3.C-F.[14] AFT FLOOR PANEL 242VF WITH MULTIPLE AREAS OF PULLED STRANDS ON THE UPPER SURFACE WAS REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>CURE SHEETS UPLOADED.;[15] VERIFIED CORRECTIVE ACTIONS. JOB COMPLETE.