What was found
AFT FLOOR PANEL 242XF TOP SURFACE IS CRACKED.<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 6 TABLE 6.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.B.<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-6.<BR>REMOVED DAMAGED SKIN AND CORE; CLEANED REPAIR AREA; FABRICATED CORE PLUG USING BMS 8-124 C4 T5 G9 LOT#1287137 AND UPPER SURFACE REPAIR PLIES USING BMS 9-3H2 LOT#1522395-2 IAW SRM 53-00-50-2R-6 PARA 3.C-G(1).<BR>OK TO INSTALL.;;[06] CURED REPAIR WITH THERMOMETER ID:ATS2208 CAL DUE 10/2023; SANDED CORE PLUG CONTOUR TO SURFACE; CLEANED REPAIR AREA AND FABRICATED LOWER SURFACE REPAIR PLIES IAW SRM 53-00-50-2R-6 PARA 3.I(1)-K(1).<BR>OK TO INSTALL.;[07] INSPECTED AND VERIFIED CORRECTIVE ACTION 6. OKAY TO INSTALL LOWER SURFACE REPAIR PLIES.<BR><BR>VERIFIED MEASUREMENTS TABLE.;[08] INSTALLED LOWER SURFACE PLIES USING BMS 8-201TY4 LOT#1524543-1; VACUUM BAGGED; LEAK CHECK GOOD WITH VACUUM GAUGE ID:ATS2441 CAL DUE 08/2023 IAW SRM 53-00-50-2R-6 PARA 3.K(1)-L(1).;[09] INSPECTED AND VERIFIED CORRECTIVE ACTION 8.;[10] CURED REPAIR PLIES USING THERMOMETER ID:ATS2208 CAL DUE 10/2023 ; UNBAGGED AND TRIMMED EXCESS MATERIAL IAW SRM 53-00-50-2R-6 PARA 3.M(1)