What was found
CRACKED INTERCOSTAL NEAR FASTENER HOLE; BS 277+7; LBL 3; WL 208.<[01] AFTER FURTHER INVESTIGATION FOUND CRACK ON INTERCOSTAL NEAR FASTENER HOLE BS277+7 LBL 3 WL208 TO BE LOCATED AT BS277+7 BL0; WL 208.1;[02] REMOVED INTERCOSTAL FROM BS277-BS294.5 BL0 IAW SRM 51-40-02;[03] VERIFIED CORRECTIVE ACTION 1 AND 2.;[04] LOCATED AND DRILLED NEW INTERCOSTAL PN#141A5410U3 FROM BS277-BS294 BL0 IAW SRM 51-40-05 AND IAW DWG#141A5400. OK TO INSTALL;[05] VERIFIED CORRECTION ACTION ITEM 4 AND OK TO INSTALL GIVEN.;[06] INSTALLED INTERCOSTAL PN#141A5410U3 FROM BS277-BS294 BL0 IAW SRM 51-40-05 AND IAW DWG#141A5400;[07] UPDATED MEASUREMENT TABLE;[08] TASK IS COMPLETE.;[09] VERIFIED MEASUREMENT TABLE.